Contact Us
- Building B, No. 17, Zijing Road, Pingxi, Pingdi Street, Longgang District, Shenzhen
- 934728633@qq.com
- +0755-29698036
BWVB20 Rebound Series
Parameters | BWVB20 series rebound type | |||||
Measurement range mm | 2.5 | 5 | 10 | 15< /td> | 25 | 50 |
Outline length A (mm) | 80 | 90 | 110 | 130 | 170 | 210 |
Natural exposed length B (mm) | 20 | 30 | 40 | 50 | 70 | 80 |
Note: The factory default setting is that the output increases when the sensor guide moves in the direction of the outlet. The above dimensions are limited to analog output. If it is a digital output product, the length A needs to be extended by 62mm.
Note: Standard outer diameter = 20mm. Other dimensions can be customized on demand.
Detailed Introduction
LVDT | BWVB20 rebound differential transformer displacement sensor |
Measurement range | 2.5mm; 5mm; 10mm; 15 mm; 25mm; 50mm optional |
Ambient temperature | -20℃~80℃ |
Protection level | IP67 |
9-28VDC | |
Working current | Voltage output type supply current <=12mA |
Two-wire 4-20mA current output LVDT, power supply current 4-20mA | |
Output signal | DC power supply voltage) |
DC power supply voltage) | |
(two-wire system, 15-28V DC power supply voltage) | |
(9-12V DC power supply voltage) | |
Linearity error | Analog output: ±0.25% , ±0.5% and other optional; digital output: 0.25%, 0.1% and other optional |
resolution | <=0.01% (highest), digital output is 16bit |
Repeat error | 5μm |
Installation method | Use non-metallic clamps with a small temperature expansion coefficient to fix it. |
You might also like
Send Inquiry